Dräger Savina Ventilator
   

Basic Description

 
 
Manufacturer:  Dräger Medical, Inc.
Ventilator Type:  Positive Pressure
Invasive
Conventional
Ventilator Class:  Intensive Care Unit (ICU)
Transport
Subacute
CPAP
BiPAP
Patient Population Range:  Pediatric
Adult
Acute
 

Characteristics

 
Modes--Invasive:  Pressure-controlled modes --- IPPV (CMV); IPPVAssist (A/C); SIMV; SIMVAssist (SIMVPS, CPAP; CPAPASB (CPAPPS); BIPAP (PCV+) (optional); IPPV (CMV); IPPVAssist (A/C); SIMV; SIMVAssist (SIMVPS; CPAP; CPAPASB (CPAPPS); BIPAP (PCV+) (optional); BIPAPASB (PCV+PS) (optional)
Supplemental modes --- Autoflow(tm) --Automatic adaptation of the inspiratory flow in volume oriented modes of ventilation
Operating Range of Controls:  Ventilation frequency: 2 - 80 bpm; Inspiration time: 0.2 - 10 s; Tidal Volume: 0.05 - 2.0 L, BTPS1; Inspiratory flow: 0 - 180 L/min; Inspiratory pressure: 0 - 100 mbar2; PEEP/interm. PEEP: 0 - 35 mbar; Pressure support/ASB: 0 - 35 mbar (relative to PEEP); Flow acceleration: 5 - 200 mbar/s; O2 concentration: 21 - 100 Vol.%; Trigger Sensitivity: 1 - 15 L/min; 1BTPS: Body Temperature Pressure Saturated. Measured values relating to the conditions of the patient lung. Body temperature 37°C, steam-saturated gas, ambient pressure. 2 1 mbar = 100 Pa
Graphic Display:  Curve displays: Airway pressure/time, flow/time
Size:  360 W x 330 H x 290 D mm
Weight:  approx. 22 kg
Other Characteristics:  Other monitored variables: Inspiratory O2: 15 -100 Vol.%; Breathing gas temperature: 18 - 51° C (sensor optional); Ventilation ratio (I:E): 11:1 - 1:150

Specifications

Power Requirements:  Electrical: 100 V - 240 V, 50/60 Hz AC; 12 - 24 V DC; Internal battery: approx. 45 minutes (optional extension to 7 hours); Pneumatic: Air: turbine technology; O2: 3 bar -10% up to 6 bar/39 - 87 psi
Alarms:  Airway pressures: high/low; Expiratory minute volume: high/low; Tidal volume: high/low; Apnea-alarm time: 15 - 60 sec; Spontaneous breathing frequency: high; Inspiratory O2 concentration: high/low; Inspiratory breathing gas temperature: high
Interface Ports:  RS 232 C
Other Specifications:  Performance Data: Maximum flow for pressure assist/spontaneous breathing: 180 L/min; Valve response time T0...90: 2 supply fails; Automatic gas switch-over function if O2 supply fails; Output for pneumatic medicament nebuliser: synchronized with inspiration

Monitored Variables :

Pressure Peak pressure; plateau pressure, mean airway pressure, PEEP 0 - 99 mbar
Respiratory Rate Total and spontaneous breathing frequency, 0 - 150 bpm
Tidal Volume Inspiratory VT, Expiratory VT 0 - 3999 mL, BTPS
Minute Volume Total MV, spontaneous MV, 0 - 99 L/min, BTPS