Model:  Puritan-Bennett Option 60, Graphics
 
Manufacturer:  Puritan Bennett Corporation
Accessory Type:  Supplies (Miscellaneous)
For use with:  Puritan-Bennett 7200spe Ventilator
 

Description

Brief Description:  Graphics 1.0: Menu selection of six types of waveform curves or loops: pressure, flow, volume, or SpO2 plethysmogram vs. time and pressure-volume or flow-volume loops; Breath-by-breath display of waveform curves; Display of up to two waveform-time curves; PEEP compensation for pressure-volume loop; Adjustable scale and time interval selection; Measure inspiratory area (ventilator-imposed work to trigger and/or sustain a breath); Screen Freeze and print capability (with optional printer); Graphics 2.0; Select up to 12 parameters for trending from a menu of over 30 parameters; Move a cursor to identify individual data points of a displayed trend; Select the scales and time ranges for waveform curves and trended parameters
 

Specifications

Other Specifications:  Requires a 7200spe Ventilator with a 7202 Display. Waveforms Menu: Time Curves: Pressure vs. time; Flow vs. time; Volume vs. time; SpO2 Plethysmogram (when Pulse Oximetry is active); Loops: Pressure vs. volume (PEEP compensated); Flow vs. volume; Scale factors: Time interval: 6, 12, or 24 seconds; Pressure range: -10 to 30 cmH2O; -20 to 60 cmH2O; -40 to 120 cmH2O; Flow range: 60, 120, or 180 Lpm; Volume range: 0.2 to 0.6 liters; 0.4 to 1.2 liters; 1.0 to 3.0 liters; Graphics 2.0 Trending Parameters: Select up to 12 parameters at a time. Selected parameters are trended for up to 72 hours. One or two of the trended parameters can also be displayed graphically. Total respiratory rate; Mandatory tidal volume; Spontaneous respiratory rate; Spontaneous tidal volume; Spontaneous minute volume; Total minute volume; Mean airway pressure; Peak inspiratory pressure; Plateau pressure; I:E ratio; PEEP; Auto-PEEP; Total PEEP; SpO2; Pulse rate; Set respiratory rate; Set tidal volume; Set peak flow; Set FIO2; Set plateau time; Set pressure support level; Set pressure control ventilation (PCV) inspiratory pressure; Set PCV inspiratory time; Set PCV I:E ratio; Dynamic compliance; Dynamic resistance; Static compliance; Static resistance; Negative inspiratory pressure; Vital capacity; Peak spontaneous flow; RR/VT (rapid shallow breathing index); TI/TTOT (fraction of inspiratory time to total cycle time; VT/VI (mean inspiratory flow); VO2 (oxygen consumption); VCO2 (carbon dioxide production); RQ (respiratory quotient); EE (energy expenditure); ETCO2 (end tidal CO2)

Related Info 

Distributor | Educator | Manufacturer |Rental Agent | Service Center |
Parts Available | Product Markets | Service Centres |

Manufacturer:

Puritan Bennett Corporation
2200 Faraday Avenue
Carlsbad, CA
USA