Model:  Siemens CO2 Analyzer Module for Servo Screen 390
 
Manufacturer:  MAQUET GmbH & Co. KG
Accessory Type:  Monitors
For use with:  Siemens Servo 300 Ventilator
 

Characteristics

Graphic Display:  The CO2 analyzer module presents the following on the Servo Screen 390: CO2 concentration - Time waveform (capnogram) depicting the variation in airway CO2 level during the patient's respiratory cycle; CO2 concentration - Expired volume waveform (single breath carbon dioxide waveform); End-tidal CO2 concentration (etCO2)
Size:  CO2 analyzer module: 150 x 93 x 70 mm; Sensor: 32 x 42 x 22 mm
Weight:  CO2 analyzer module: 0.45 kg; Sensor: <18 g; Adapter: 10 g
Other Characteristics:  Also monitors Airway Dead Space (VDaw), End Tidal CO2 concentration (etCO2%), Capnogram (CO2conc-Time waveform, SBCO2 (CO2conc-Exp. volume waveform, single breath carbon dioxide waveform) and Alveolar Ventilation (VA). Oxygen concentration and barometric pressure compensation are automatic from values supplied by the SV300 system.

Characteristics (Non - Technical)

Other Comments:  CO2 analyzer module kit for attachment to the Siemens Servo Screen 390 with software memory card, version 2.0 or higher: etCO2 Capnostat III sensor with 2.4 m cable; etCO2 airway adapter, adult (reusable); CO2 analyser module; Holder for CO2 analyser module; Calibration and reference cell; Cable clips, 5 each; 24 V power branch cable, 1.2 m; Operating manual (six language versions); Neonatal airway adapter (reusable) can be ordered separately

Specifications

Power Requirements:  CO2 analyzer module: Supply voltage: Powered from the SV300; Power: Warmup: 7 W; During normal working conditions: 4 W; Sensor: Powered from the CO2 analyzer module
Languages:  For the software upgrade kit for the SS390, version 2.0, (software memory card and operating manual): English, German, French, Spanish, Italian, Swedish
Non-Adjustable Alarms:  etCO2: %: minimum 0.5, maximum 20; mm Hg: minimum 4, maximum 100; kPa: minimum 0.5, maximum 14
Other Specifications:  Operating and Storage Conditions: CO2 analyzer module, including sensor: Operating: 10° to 40°C, 20% to 90% relative humidity, non-condensing; Storage: -20° to 50°C, 20% to 95% relative humidity, with packaging; CO2 analyzer module, including adaptor: Operating: 700 to 1060 hPa (525 to 795 mmHg) atmospheric pressure; Storage: 500 to 1060 hPa (325 to 795 mmHg) atmospheric pressure Warm-up time: 30 seconds to initial CO2 indication; maximum 5 minutes to full specification Airway adapter deadspace: Adult: <5 cm3; Neonate: <0.5 cm3

Monitored Variables :

Tidal Volume CO2 Tidal Production; Alveolar Tidal Volume (VTA)
Minute Volume CO2 Minute Production

Related Info 

Distributor | Educator | Manufacturer |Rental Agent | Service Center |
Parts Available | Product Markets | Service Centres |

Manufacturer:

MAQUET GmbH & Co. KG
Kehlerstraße 31
Rastatt,
Germany