Puritan-Bennett Infant Star 100 Ventilator System
   

Basic Description

 
 
Manufacturer:  Puritan Bennett Corporation
Ventilator Type:  Positive Pressure
Invasive
Conventional
Ventilator Class:  Intensive Care Unit (ICU)
Transport
CPAP
Patient Population Range:  Neonatal
Pediatric
 

Characteristics

Operating Range of Controls:  Inspiratory Time: 0.2 to 30 seconds; Expiratory Time: 0.2 to 30 seconds; Ventilator Rate: 2 to 150 bpm determined from inspiratory and expiratory time settings; Flow: 0 to 15 Lpm; PEEP/CPAP: 0 to 60 cmH2O; Peak Inspiratory Pressure: 0 to 60 cmH20
Size:  7.25" H x 8.5" W x 4" D (18 x 22 x 4 cm)
Weight:  7 lb (3.2 kg)
Other Characteristics:  Tracking Relief Valve: Limits airway pressure at 10 cmH20 above PIP; Internal Safety Relief: Limits breathing circuit from excessive subambiant pressure (-2 to -5 cmH2o) and excessive positive pressure (72 to 92 cmH20)

Characteristics (Non - Technical)

Warranty Period:  One year (parts and labor)
Other Comments:  Breathing circuit, exhalation valve (reusable), high pressure hose(s), and 115 V or 230 V battery charger/power supply are included with each ventilator.

Specifications

Front Panel Controls:  nspiratory Time; Expiratory Time; Ventilator Rate; Flow; PEEP/CPAP; PIP (Peak Inspiratory Pressure); Manual Breath; Proximal Airway Pressure
Power Requirements:  Electrical Power Internal Battery Operation: Rechargable gel-cell battery offering 6 to 8 hours of continuous operation; Battery Charger/Power Supply (included): 120 VAC, 60 Hz, 0.18 amp; 230 VAC, 50/60 Hz, 0.125 amp Allows recharging during ventilator operations/standby Pneumatic Power Internal: 40 to 70 psig (276 to 483 kPa) blended Air/O2; Bleed flow: 6 Lpm (maximum)
Languages:  English, Russian, Japanese
Alarms:  General System Failure; Additional General System Alarms; Low Peak Pressure; Low PEEP; Apnea (optional)
Alarm Controls:  Low Pressure Alarm Delay: 0 to 40 seconds; Proximal Airway Pressure: -20 to 100 cmH20
Non-Adjustable Alarms:  Low Pressure Alarm Delay: 0 to 40 seconds; Proximal Airway Pressure: -20 to 100 cmH20
AC Power and Battery Indicators:  Amber with external AC power
Other Specifications:  Other indicators: Battery Low Alarm: flashes red when charging is required; Inspiratory LED: glows amber during mandatory inspiratory phase; Battery Charging: indicates battery charging status