| Respironics PLV-102 Ventilator | |||
Basic Description | |||
| Manufacturer: | Respironics | ||
| Ventilator Type: | Positive Pressure | ||
| Ventilator Class: | Transport Subacute Home | ||
| Patient Population Range: | Adult Acute | ||
Characteristics | |||
| Modes--Invasive: | Volume-controlled modes --- CONTROL; ASSIST/CONTROL; SIMV Pressure-controlled modes --- CONTROL; ASSIST/CONTROL; SIMV | ||
| Waveforms: | Sine Wave Flow With Sigmoidal Pressure Pattern | ||
| Operating Range of Controls: | Tidal Volume: 50 to 1800 ml; Rate: per min.2 to 40; Peak Flow Rate: 10 to 120 liters/min.; Sensitivity: -5 to +18 cmH2O; Sigh Volume: 1.5 ml * set Tidal Volume; Sigh Rate: 1/100 breaths | ||
| Size: | 22.9 x 31.1 x 31.1 (cm) | ||
| Weight: | 13.1 (kg) | ||
Characteristics (Non - Technical) | |||
| List Price: | $15750 | ||
| Warranty Period: | 1 year | ||
| Other Comments: | Monthly maintenance contract. Was formerly manufactured by Lifecare. | ||
Specifications | |||
| Front Panel Controls: | Mode Selection: Control, Control + Sigh, Assist/Control, Assist/Control + Sigh, SIMV; Tidal Volume: 0.05 to 0.20 +/- 0.02 liters; 0.20 to 3.00 liters +/- 10%; Sign Volume: 150% of Set Tidal Volume; Sign Frequency: 1 Sign Breath every 100 Tidal; Breath Rate: 2 to 35 BPM +/- 0.5; 36 to 40 BPM +/- 2; Inspiratory Flow Rate*: 10 to 120 LPM; Battery Test Switch: Test Internal/External Battery; Main Power Switch: On/Off, Recharge; DC Circuit Breaker: Push/Pull Actuation; AC Circuit Breaker: Push/Pull Actuation; Airway Pressure Limit: 5 to 100 cm H2O +/- 5; Sensitivity: +18 cm H2O +/- 1 to at least -6 cm H2O; Low Pressure Alarm: 2 to 40 cm H2O +/- 2; 41 to 50 cm H2O +/- 5; Manual Sigh: Push to Activate One Breath; Oxygen Percent**: 21% to 90% +/- 6%; Oxygen Sensor (SIMV Operation)**: 21% to 90% +/- 10%; 30 Second Alarm Silence: Push to Activate; (* Peak flow rate during inspiratory time); (**See Operators Manual for Oxygen Delivery Limitations.); | ||
| Display Monitor Controls: | Manual Sigh: Yellow Indicator Light; Tidal Volume: Digital Display; Rate: Patient Breaths Per Minute: Digital Display; I:E Ratio: Digital Display; Inspiratory Flow Rate: Digital Display; Increase Inspiratory Flow: Red Indicator Light; 120 VAC Power Source: Green Indicator Light; Internal DC Power Source: Amber Indicator Light; External DC Power Source: Yellow Indicator Light; Patient Airway Pressure*: -10 to 100 cm H20 ±5; Assisted/Spontaneous: Green Indicator Light; 15-Second Delay (Low Pressure Alarm): Green Indicator Light; Oxygen Percent: 50% and Greater Marked Red; 30-Second Alarm Silence: Yellow Indicator Light/Push Button; Alarm Code Display(in Flow Window): Digital Display; (* Pressure waveform is sinusoidal). | ||
| Alarms: | Low Pressure: Visual/Continuous Audible; High Pressure: Intermittent Audible; Apnea: Visual/Continuous Audible; Inverse I:E Ratio: Visual Warning; Increase Inspiratory Flow: Visual Warning; Low Internal Battery: Visual/Continuous Audible; Low External Battery: Visual/Continuous Audible; Reverse Battery Connection: Continuous Audible; Power Failure: Continuous Audible; Unit Malfunction: Intermittent Audible; Power Source Change: Continuous Audible; Oxygen: Continuous Audible | ||
| Other Specifications: | Internal battery duration 1 hour, external battery duration 24 hours | ||