| Puritan-Bennett Infant Star 200 Ventilator | |||
Basic Description | |||
| Manufacturer: | Puritan Bennett Corporation | ||
| Ventilator Type: | Positive Pressure Invasive Conventional | ||
| Ventilator Class: | Intensive Care Unit (ICU) Subacute CPAP | ||
| Patient Population Range: | Neonatal Pediatric Acute Long-term (chronic) | ||
Characteristics | |||
| Modes--Invasive: | Pressure-controlled modes --- ASSIST/CONTROL; SIMV; CPAP (these require Star Sync); IMV; CMV Supplemental modes --- CPAP (not controlled) | ||
| Waveforms: | Pressure: Rectangular; Flow: Rectangular | ||
| Operating Range of Controls: | Ventilator Rate: 1 to 150 bpm; Inspiratory Time: 0.1 to 2.9 seconds; Flow: 0 to 50 Lpm; PEEP/CPAP: 0 to 20 cmH20; PIP (Peak Inspiratory Pressure): 0 to 70 cmH2O; I:E Ratio: 1:0.25 to 1:9.9; Mean Airway Pressure: 0 to 99.9 cmH2O | ||
| Size: | 9" (23cm) H x 15.5" (39cm) W x 10" (25cm) D | ||
| Weight: | 17 lb (7.7 kg) without blender; 20 lb (20 kg) with blender | ||
| Other Characteristics: | Safety features: Tracking relief valve: Limits airway pressure at 10 cm H2O above PIP; Internal safety relief: Limits breathing circuit from excessive subambiant pressure (-2 to -5 cmH2O) and excessive positive pressure (72 to 92 cmH2O) | ||
Characteristics (Non - Technical) | |||
| Other Comments: | Each ventilator comes with breathing circuit, reusable exhalation valve, high pressure hoses, and test lung. | ||
Specifications | |||
| Front Panel Controls: | Ventilator Rate; Inspiratory Time; Flow; PEEP/CPAP; PIP (Peak Inspiratory Pressure); Manual Breath (delivers single mandatory breath); I:E Ratio; Mean Airway Pressure | ||
| Power Requirements: | Electrical Power: 108 to 132 VAC, 60 Hz; 207 to 242 VAC, 50/60 Hz or 12 VDC, 2.5 amp; Pneumatic Power: Internal: 40 to 70 psig (275 to 481 kPa); Bleed Flow: 4 to 7 Lpm w/o blender, 12 to 15 Lpm w/blender | ||
| Alarms: | Low Pressure Alarm Silence: 60 seconds | ||
| Alarm Controls: | Proximal Airway Pressure: -20 to 100 cmH2O; High Pressure Alarm: 1 to 85 cmH2O; Low Pressure Alarm: 1 to 85 cmH2O | ||
| Non-Adjustable Alarms: | Insufficient Expiratory Time: Preset at 0.2 seconds; Low Inlet Pressure: Preset for 40 psig inlet pressure; Max Inverse I:E Ratio: Preset for ratios >4:1; Power Loss: Insufficient AC or DC power; Ventilator Inop: Malfunction detected by microprocessor | ||
| Mounting Options: | Star cart (with or without electrical outlet), pedestal | ||
Monitored Variables : | |||
| Pressure | Mean airway pressure (digital), airway pressure (aneroid gauge) | ||