Bear 1000 Ventilator: Basic Model
   

Basic Description

 
 
Manufacturer:  Bear Medical Systems Incorporated
Ventilator Type:  Positive Pressure
Invasive
Conventional
Ventilator Class:  Intensive Care Unit (ICU)
CPAP
Patient Population Range:  Pediatric
Adult
 

Characteristics

 
Modes--Invasive:  Volume-controlled modes --- ASSIST/CMV; SIMV/CPAP (PSV)
Combined modes --- PRESSURE AUGMENT (pressure/volume control)
Waveforms:  Square, Decelarating, Sine
Operating Range of Controls:  Tidal Volume: 0.10 to 2.00 L; Rate: 0, 0.5, 1 to 120 BPM; Peak Flow: 10 to 150 LPM; %O2: 21 to 100%; Pressure Support:0 to 80 cmH2O; Assist Sensitivity: 0.2 to 5 cmH2O; PEEP/CPAP: 0 to 50 cmH2O; Manual Breath: x1; Manual Inspiratory Pause: 2 Seconds Maximum; 100% O2: On/Off-3 Minutes Auto Off; Sighs: On/Off, Every 100 breaths at 150% of set Tidal Volume; Nebulizer: On/Off-30 Minutes Auto Off; Panel Lock: On/Off; Set Knob: No End Stop
Graphic Display:  Waves Page Flow, Volume, and Pressure (AW) waveforms with user adjustable waveforms scales and sweep speed Loops Page Pressure/Volume AW (airway pressure) Flow Volume Monitoring Data VTI, VTE, PIFR, PIP, PEEP Mechanics Data CRS: Static Compliance 0 to 300 ml/cmH2O RRS: Resistance of the Respiratory System 0 to 100 cmH2O/L/sec
Size:  23"W x 13.5" D x 15"H
Weight:  54 lbs.
Power:  AC 110V/60Hz

Characteristics (Non - Technical)

List Price:  $19500
Approvals:  IEC UL
Other Comments:  Price is for ventilator only; no major maintenance required; preventative maintenance kit every year

Specifications

Power Requirements:  95 - 135V, 60 Hz (U.S./ International); 80 - 110V, 50/60 Hz (International); 176 - 242V, 50/60 Hz (International); 192 -264V, 50/60 Hz (International)
Alarms:  Time I/E Limit; Run Diagnostics; Gas Supply; Failed to Cycle; I/E Override
Alarm Controls:  Total Minute Volume: High 0 to 80 LPM, Low 0 to 50 LPM; Total Breath Rate: High 0 to 155 BPM, Low 1 to 99 BPM; Peak Inspiratory Pressure: High 0 to 120 cmH20, Low 3 to 99 cmH2O
Non-Adjustable Alarms:  Time/I:E Limit; Run Diagnostics; Gas Supply; Failed to Cycle

Monitored Variables :

Respiratory Rate 0 to 155 BPM
Tidal Volume 0.00 to 9.99 L
Minute Volume 0.0 to 99.9 LPM

Related Info 

Distributor |Educator | Manufacturer |Rental Agent | Service Center |
Parts Available | Product Markets | Service Centres |

Distributor:

Intermed
Av. Cupecê, 1786 - CEP
São Paulo, SP
Brazil



Distributor:

Breath of Life
12151 S.W. 131 Ave.
Miami, FL



Manufacturer:

Bear Medical Systems Incorporated
1100 Bird Center Drive
Palm Springs, CA
USA